CHAPTER 3: Configuring the Thermostat Using the TMI
Use
location and enable or disable alarm settings and filter replacement reminders.

Table 3-2 General Settings Field Descriptions

Field
Zone Name
Device Name
Site Name
Thermostat
Serial Number
SW Ver / HW Rev
Temperature Scale
Display Contrast
Alarms
Low Temp(erature) Limit
3-14
Table 3-2
to set the General Settings parameters such as the thermostat name and
Basic Series Network Thermostat Configuration Guide, Release 3.0
Beta Draft Confidential
Description
Enter a unique 13 character identifier for the thermostat. You can
use the thermostat location in this field (i.e. Main Lobby). This
identifier is known as the host name within the data network.
Enter a 25 alpha-numeric character name used to identify the
thermostat if more than one thermostat intercommunicates with
the Proliphix Web Server. (See the Proliphix Remote Access
Guide.)
Displays an eight digit alpha-numeric thermostat serial number
(e.g. 8438F399).
Displays the software version / hardware revision .
Select either the Fahrenheit or Celsius temperature scales.
Fahrenheit (default) – All thermostat temperature readings
and reporting are displayed in the Fahrenheit temperature
°
scale (
F).
Celsius – All thermostat temperature readings and reporting
are displayed in the Celsius temperature scale (
Select a value between 20 (lowest contrast between the graphics
characters and the background) and 40 (highest character
contrast to the background) to indicate the LCD display contrast
control.
20, 22, 24, 26, 28 (default), 30, 32, 34, 36, 38, 40
Select a value or Disable to indicate the low temperature
threshold detection status. The value set by this parameter is
monitored by the thermostat and compared against the current
Zone
Temperature. If the current
this value, an alarm condition is set and the status is displayed on
the
Status & Control Page (page
be sent to the Proliphix web site to trigger an email notification if
this function is Enabled.
This is a major (red) alarm condition. (See
page
3-13.)
Disable (default) – No low temperature limit is set.
°
°
°
-30
F(-34.5
C) to 200
F(93
Part No. 600-01000-201, Rev. 1
°
C).
Zone Temperature
falls below
3-9). In addition, this alarm will
Figure 3-4 on
°
C)