Advertisement

CHAPTER 3: Configuring the Thermostat Using the TMI
Table 3-1 Thermostat Status Field Descriptions (Continued)
Field
High Temperature
Filter Change
3-12
Beta Draft Confidential
Description
Displays the current status of the High Temperature alarm condition. The
zone temperature has risen above a pre-programmed limit. After this alarm
occurs, you must repair the condition which caused the temperature to rise
above the configured limit before resetting this alarm. (See
Page (page
3-13).)
OK – No High Temperature alarm exists.
Alert! – The temperature monitored within the thermostat has risen
above the pre-set high temperature threshold.
Displays a reminder that the time interval between HVAC filter changes has
expired. The air filter(s) should be cleaned or replaced. You should change
the filter and then reset this timer. (See
OK – No filter change is required.
Required! – The HVAC filters require changing or cleaning.
Basic Series Network Thermostat Configuration Guide, Release 3.0
General Settings
General Settings Page (page
3-13).)
Part No. 600-01000-201, Rev. 1