The overall dimensions are shown in Fig.1
Figure 1 Overall Dimensions
Gas
Inlet pressure:
Input (gross)
:
Output:
Injectors:-
2.1
The installation must be in accordance with
these instructions.
For the user's protection, in the United Kingdom it is
the law that all gas appliances are installed by competent
persons in accordance with the current edition of the
Gas Safety (Installation and Use) Regulations. Failure to
install the appliance correctly could lead to prosecution.
The Council for the Registration of Gas Installers
(CORGI) requires its members to work to recognised
standards.
2.2
In the United Kingdom the installation must
also be in accordance with:
a) All the relevant parts of local regulations.
b) The current edition of the Building Regulations
issued by the Department of the Environment and
the Welsh Office or the Building Standards
(Scotland) (Consolidation) Regulations issued by the
Scottish Development Department.
4
1.
G20
20mbar
Max. 5.28kW
Min. 1.25kW
Max. 3.2kW
Min. 0.56kW
Upper (Centre
radiant) Bray cat. 28
size 120
Lower ( Outer
radiants) Bray cat. 28
size 250B
2

GENERAL INSTALLATION REQUIREMENTS

APPLIANCE DATA

Pressure Setting Cold:-
Inlet connection:
Pilot & atmospheric sensing
device:
Ignition:
Aeration Adjustment:
No component on this appliance is manufactured from
asbestos or asbestos related products.
The appliance data label is on the air guide plate at the
left side and is visible after removing the case. There is
also a label giving serial number on the right side of the
outer case near the bottom.
c) All relevant codes of practice.
d) The relevant parts of the current editions of the
following British Standards:-
BS 715
BS 1251
BS 1289 Part 1
BS 1289 Part 2
BS 4543 Part 2
BS 5440 Part 1
BS 5440 Part 2
BS 5871 Part 1
BS 6461 Part 1
BS 6891
In the republic of Ireland the installation must also
conform with the relevant parts of:
a) The current editions of:-
IS 813
ICP3
b) All relevant national and local rules in force.
18.3 + 1.0mbar
(7.2 +0.4in. w.g)
1/4" BSP
SIT ref. OP9044
Piezo electric integral
with gas tap
None required.