Appliance Data; General Installation Requirements - Valor 4190 Installer's Manual

For natural gas, for propane gas inset live fuel effect gas fires with ultimatefireslide or fusion front
Hide thumbs Also See for 4190:
Table of Contents

Advertisement

This product uses fuel effect pieces, burner compartment walls and gaskets containing
Refractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibres.
Excessive exposure to these materials may cause temporary irritation to eyes, skin and
respiratory tract. Consequently, it makes sense to take care when handling these articles
to ensure that the release of dust is kept to a minimum. To ensure that the release of
fibres from these RCF articles is kept to a minimum, during installation and servicing
we recommend that you use a HEPA filtered vacuum to remove any dust and soot
accumulated in and around the fire before and after working on the fire. When replacing
these articles we recommend that the replaced items are not broken up, but are sealed
within a heavy duty polythene bag, clearly labelled as RCF waste. This is not classified
as "hazardous waste" and may be disposed of at a tipping site licensed for the disposal of
industrial waste. Protective clothing is not required when handling these articles, but we
recommend you follow the normal hygiene rules of not smoking, eating or drinking in
the work area and always wash your hands before eating or drinking.
This appliance does not contain any component manufactured from asbestos or
asbestos related products.
The appliance data label is chained below the burner and is visible when the bottom
front cover is removed.
Gas
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Output - Max.
Output - Min
Burner
(Cold)
Gas Connection
Burner Injector
Pilot
Sensing Device
Ignition
Aeration
2.

GENERAL INSTALLATION REQUIREMENTS

2.1
For the user's protection, in the United Kingdom it is the law that all gas appliances are
installed by competent persons in accordance with the current edition of the Gas Safety
(Installation and Use) Regulations. Failure to install the appliance correctly could lead
to prosecution. The Council for the Registration of Gas Installers (CORGI) requires
its members to work to recognised standards.
In the United Kingdom the installation must also be in accordance with:
a) All the relevant parts of local regulations.
b) The current edition of the Building Regulations issued by the Department of the
Environment and the Welsh Office or the Building Standards (Scotland)
Regulations issued by the Scottish Development Department.
c) All relevant codes of practice.
1.

APPLIANCE DATA

Natural (G20)
20mbar
6.0kW (20,500Btu/h)
2.7kW (9,200Btu/h)
3.5kW (11,900Btu/h)
1.3kW (4,450Btu/h)
Test
Pressure
17.0±0.75mbar (6.8±0.3in
w.g.)
8mm pipe
Bray Cat. 82 Size 400
&
Atmosphere
SIT Ref. OP9030
Piezo Electric. Integral with
Gas Tap
Non-adjustable
The installation must be in accordance with these instructions.
4
Model 4190
Propane (G31)
37mbar
6.1kW (20,800Btu/h)
4.3kW (14,650Btu/h)
3.17kW (10,800Btu/h)
2.24kW (7,600Btu/h)
36.0±0.75mbar
(14.45±0.3in w.g.)
8mm pipe
Bray Cat. 92 Size 190
SIT Ref. OPLPG9221
Piezo Electric. Integral with
Gas Tap
Non-adjustable
Model 4191