HPOD C, X-, or Ku-Band High-Power Outdoor Amplifier
Ethernet-based Remote Product Management
The HPOD uses these Faults v1 traps and v2 notifications:
Faults SNMPv1 traps:
hpod24VPowerSupplyStatusV1
hpod15VPowerSupplyStatusV1
hpod10V1PowerSupplyStatusV1
hpod10V2PowerSupplyStatusV1
hpod7V5TPowerSupplyStatusV1
hpod5VPowerSupplyStatusV1
hpodN5VPowerSupplyStatusV1
hpodFan1StatusV1
hpodFan2StatusV1
hpodTemperatureStatusV1
hpodShutdownStatusV1
hpodIICStatusV1
hpodFwdPwrStatusV1
hpodBUCStatusV1
hpodRefStatusV1
hpodSummaryFaultV1
4.4
Telnet Interface
The HPOD has a Telnet interface for the equipment M&C operations. Log in to the Telnet
interface at the Administrator level or Read/Write level. An example of the login process is
shown here:
After you log into the Telnet interface as the Administrator, you can use the standard remote
control interface, defined in Chapter 5. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT, as
shown here:
Faults SNMPv2 notifications:
62476201
hpod24VPowerSupplyStatus
62476202
hpod15VPowerSupplyStatus
62476203
hpod10V1PowerSupplyStatus
62476204
hpod10V2PowerSupplyStatus
62476205
hpod7V5TPowerSupplyStatus
62476206
hpod5VPowerSupplyStatus
62476207
hpodN5VPowerSupplyStatus
62476208
hpodFan1Status
62476209
hpodFan2Status
62476210
hpodTemperatureStatus
62476211
hpodShutdownStatus
62476212
hpodIICStatus
62476213
hpodFwdPwrStatus
62476214
hpodBUCStatus
62476215
hpodRefStatus
62476216
hpodSummaryFault
4–4
Revision 6
MN/HPOD.IOM
1.3.6.1.4.1.6247.62.1.3.1.1
1.3.6.1.4.1.6247.62.1.3.1.2
1.3.6.1.4.1.6247.62.1.3.1.3
1.3.6.1.4.1.6247.62.1.3.1.4
1.3.6.1.4.1.6247.62.1.3.1.5
1.3.6.1.4.1.6247.62.1.3.1.6
1.3.6.1.4.1.6247.62.1.3.1.7
1.3.6.1.4.1.6247.62.1.3.1.8
1.3.6.1.4.1.6247.62.1.3.1.9
1.3.6.1.4.1.6247.62.1.3.1.10
1.3.6.1.4.1.6247.62.1.3.1.11
1.3.6.1.4.1.6247.62.1.3.1.12
1.3.6.1.4.1.6247.62.1.3.1.13
1.3.6.1.4.1.6247.62.1.3.1.14
1.3.6.1.4.1.6247.62.1.3.1.15
1.3.6.1.4.1.6247.62.1.3.1.16
Need help?
Do you have a question about the HPOD and is the answer not in the manual?
Questions and answers