HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Appendix B
Redundancy State and Mode
•
Use the drop‐down list to set the Redundancy State as Off, 1:1, or 1:2.
•
Use the drop‐down list to set the Redundancy Mode as Manual or Automatic.
Click [Change] to save these settings.
Set Switch Position (1:1 only)
In Manual Mode only – To force a unit into the active online state, use the drop‐down list to
select a unit number, and then click [Send the Command].
Gain Offset (1:1 only)
Enter the gain offset, in 0.25 dB steps, and then click [Change].
Force Back-up State (1:2 only)
Use the drop‐down list to set the back‐up state as follows:
•
Select Unit 01 or Unit 02 to put that HPOD into an offline state and set the Redundancy
Mode to Manual.
•
Select None to put the backup unit offline and set the Redundancy Mode to Automatic.
Click [Change] to save this setting.
Backup Offset for Unit 01 (1:2 only)
Enter the Backup Offset for Unit 01, in 0.25 dB steps, and then click [Change].
Backup Offset for Unit 02 (1:2 only)
Enter the Backup Offset for Unit 02, in 0.25 dB steps, and then click [Change].
Online Status
The active status for the unit is identified here as Online or Offline.
.