Comtech EF Data HPOD Installation And Operation Manual page 143

C-, x-, ku-band high-power outdoor amplifier
Hide thumbs Also See for HPOD:
Table of Contents

Advertisement

HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Appendix B
Redundancy State and Mode
Use the drop‐down list to set the Redundancy State as Off, 1:1, or 1:2.  
 
Use the drop‐down list to set the Redundancy Mode as Manual or Automatic. 
 
Click [Change] to save these settings. 
Set Switch Position (1:1 only)
In Manual Mode only – To force a unit into the active online state, use the drop‐down list to 
select a unit number, and then click [Send the Command]. 
Gain Offset (1:1 only)
Enter the gain offset, in 0.25 dB steps, and then click [Change]. 
Force Back-up State (1:2 only)
Use the drop‐down list to set the back‐up state as follows: 
 
Select  Unit  01  or  Unit  02  to  put  that  HPOD  into  an  offline  state  and  set  the  Redundancy 
Mode to Manual. 
 
Select None to put the backup unit offline and set the Redundancy Mode to Automatic. 
 
Click [Change] to save this setting. 
Backup Offset for Unit 01 (1:2 only)
Enter the Backup Offset for Unit 01, in 0.25 dB steps, and then click [Change].
Backup Offset for Unit 02 (1:2 only)
Enter the Backup Offset for Unit 02, in 0.25 dB steps, and then click [Change].
Online Status
The active status for the unit is identified here as Online or Offline. 
 
 
 
.
B–7
Revision 6
MN/HPOD.IOM