HPOD C, X-, or Ku-Band High-Power Outdoor Amplifier
Ethernet-based Remote Product Management
3. Enter the User name and password (the default for both is comtech): 
 
 
 
 
 
 
 
 
 
4. Use the LRS remote command to set the Ethernet remote control access parameter:  
 
Use default remote command LRS=3 for Serial + Ethernet control 
 
Use remote command LRS=2 for Ethernet control only.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5. If necessary, use the IPA remote command to set a unique IP address. 
 
 
 
 
 
 
 
1. Each HPOD must have a unique IP address assigned before connection 
to  a  network.  If  the  IP  address  needs  to  be  changed  from  the  factory 
default  setting,  use  the  IPA=xxx.xxx.xxx.xxx.yy  remote  command, 
where 'xxx.xxx.xxx.xxx' is  a  valid  IP  address  on  the  network  where  the 
unit will be installed, and 'yy' is the range (typically, yy=24). 
 
If you change the IPA value, make sure to shut off and restart the unit; 
2.
then, start a new Telnet session using the new IP address.
4–7
Revision 6
MN/HPOD.IOM