Comtech EF Data HPOD Installation And Operation Manual page 94

C-, x-, ku-band high-power outdoor amplifier
Hide thumbs Also See for HPOD:
Table of Contents

Advertisement

HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Serial-Based Remote Product Management
Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
Retrieve next 5
N/A
145 bytes,
unread Stored
alphanumeric
Alarms
Description of Arguments
Query only.
Reports the five oldest stored events in the alarm log, and if there are no events in the log the unit will
reply with LNA*. All events that are read from the log are also automatically removed from the log.
Reply format:
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr''lf'
Where:
YYYYYYYYYY is the fault description.
ZZ is the event type:
FT = Fault
OK = Clear
IF = Information
mmddyy hhmmss = date / time stamp.
Example:
<1/LNA?'cr'
>0001/LNA='cr'
LOG CLR IF 175503 052307'cr'
FAN #1 FT 175504 052307'cr'
OVR TMP FT 175504 052307'cr'
FAN #1 OK 175504 052307'cr'
IIC BUS FT 175504 052307'cr''lf'
5–14
Revision 6
MN/HPOD.IOM
Query
Response to
(Instruction
Response to Query
Command
& Qualifier)
N/A
LNA?
LNA=YY..ss
(See Description of
Arguments)

Advertisement

Table of Contents
loading

Table of Contents