Comtech EF Data HPOD Installation And Operation Manual page 90

C-, x-, ku-band high-power outdoor amplifier
Hide thumbs Also See for HPOD:
Table of Contents

Advertisement

HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Serial-Based Remote Product Management
Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
Auto Fault
AFR=
1 byte,
Recovery
value of 0, 1
RF Power
AMP=
1 byte,
Amplifier State
value of 0, 1
Attenuation
ATT=
5 bytes,
numerical
Gain Offset
GOF=
5 bytes,
numerical
Set Backup
SBO=
7 bytes,
Offset
numerical
Auxiliary Mute
AUX=
1 byte
Enable
value of 0,1
BUC Mute
BCM=
1 byte
State
value of 0,1
Description of Arguments
Command or Query.
Automatically mutes SSPA output in the event of detected fault. If enabled, it causes the output to go
active (un-mute) if all faults are cleared. If disabled, output remains muted even if all faults are cleared.
Example:
<1/AFR=1'cr'
>0001/AFR='cr''lf'
Command or Query.
Turn ON or OFF the RF power amplifiers, in the form x, where:
0 = Off
1 = On
Example: AMP=1'cr'
Command or Query.
Set a valid attenuation level, in 0.25 dB increments, in the form xx.xx.
Example: ATT=12.25'cr'
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB increments, in a 1:1 redundant system so power is
equal between the online and offline units when a switchover occurs, in the form xx.xx.
Example: GOF=02.00'cr'
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB increments, in a 1:2 redundant system so power is
equal between the online and offline units when a switchover occurs. In the form #,xx.xx where:
# = 1 or 2
xx.xx = level, in 0.25 dB increments
Examples: SBO=1,02.00'cr' or SBO=2,02.50'cr'
Command or Query.
Enable or disable the auxiliary mute mode, in the form x, where:
0 = Disabled
1 = Enabled
Example:(AUX Mute Enabled): AUX=1'cr'
Note: When enabled, Pin H of the J6 COMM 1 connector must be grounded to UN-MUTE unit. Otherwise,
unit will be muted, and if a mute query is given (MUT?) the response will be MUT=2 to indicate a hardware
controlled mute is present.
Command or Query.
Mute the unit, in the form x, where:
0 = BUC Muted
1 = BUC Not Muted
Example: BCM=1'cr' would allow the BUC to transmit
Note: Only active if the optional BUC is installed.
5–10
Revision 6
MN/HPOD.IOM
Query
Response to
(Instruction
Response to Query
Command
& Qualifier)
AFR=
AFR?
AFR=x
AFR?
AFR*
(See Description of
Arguments)
AMP=
AMP?
AMP=x
AMP?
AMP*
(See Description of
Arguments)
ATT=
ATT?
ATT=xx.xx
ATT?
(See Description of
ATT*
Arguments)
GOF=
GOF?
GOF =xx.xx
GOF?
GOF*
(See Description of
Arguments)
SBO=
SBO?
SBO=#,xx.xx
SBO?
SBO*
(See Description of
Arguments)
AUX=
AUX?
AUX=x
AUX?
AUX*
(See Description of
Arguments)
BCM=
BCM?
BCM=x
BCM?
BCM*
(See Description of
Arguments)

Advertisement

Table of Contents
loading

Table of Contents