Comtech EF Data HPOD Installation And Operation Manual page 145

C-, x-, ku-band high-power outdoor amplifier
Hide thumbs Also See for HPOD:
Table of Contents

Advertisement

HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Appendix B
Command
Arguments for
Parameter
(Instruction
Command or
Type
Code and
Response to
Qualifier)
Force Back-Up
FBU=
1 byte,
State
value of 0, 1, 2
Online Status
N/A
1 byte,
value of 0,1
Redundancy
RAM=
1 byte,
Mode
value of 0,1
Redundancy
N/A
1 byte,
State
value of 0, 1, 2
Set switch
SSW=
1 byte,
position
value of 0,1
Gain Offset
GOF=
5 bytes,
numerical
Set Backup
SBO=
7 bytes,
Offset
numerical
 
 
(Note that all arguments are ASCII numeric codes – i.e., ASCII codes between 48 and 57)
Query
Command or Query.
For 1:2 systems only (sent only to the BU unit).
Force one of the online units to be a backed up for maintenance and test purposes, in the form
x, where:
0 = Force BU OFFLINE and place system in AUTO mode.
1 = Force SSPA 1 OFFLINE and place system in MANUAL mode.
2 = Force SSPA 2 OFFLINE and place system in MANUAL mode.
Query only.
For 1:1 systems only (sent to both units).
Returns the online status in the form x, where:
0 = OFFLINE
1 = ONLINE
Command or Query.
For 1:1 systems only (sent to both units).
Sets or returns redundancy mode in the form x, where:
0 = MANUAL
1 = AUTO
Query only.
Returns the current redundancy state in the form x, where:
0 = OFF
1 = 1:1 Redundancy
2 = 1:2 Redundancy
Command only.
For 1:1 systems only(sent to either unit):
Only used when system is in MANUAL redundancy mode (RAM=0, both units).
Forces switch position in the form x, where:
1 = Forces switch to put SSPA 1 online
2 = Forces switch to put SSPA 2 online
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB increments, in a 1:1 redundancy system
so power is equal between the online and offline units when a switchover occurs, in the form
xx.xx.
Example: GOF=02.00'cr'
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB increments, in a 1:2 redundancy system
so power is equal between the online and offline units when a switchover occurs. In the form
#,xx.xx where:
# = 1 or 2
xx.xx = level, in 0.25 dB increments
Examples: SBO=1,02.00'cr' or SBO=2,02.50'cr'
Description of Arguments
B–9
Revision 6
MN/HPOD.IOM
Response to
Query
Response to
Command
(Instruction
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
FBU=
N/A
N/A
FBU?
ONL=
ONL?
ONL=x
ONL?
(see Description
of Arguments for
details)
RAM=
RAM?
RAM=x
RAM?
(see Description
of Arguments for
details)
N/A
RED?
RED=x
(see Description
of Arguments for
details)
SSW=
N/A
N/A
SSW?
GOF=
GOF?
GOF =xx.xx
GOF?
GOF*
(See Description
of Arguments for
details)
SBO=
SBO?
SBO=#,xx.xx
SBO?
SBO*
(See Description
of Arguments for
details)
query

Advertisement

Table of Contents
loading

Table of Contents