HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Appendix B
In  1:1  applications,  the  BU  also  stores  an  offset  value,  to  be  used  when  the  BU  replaces  the 
active  unit.  This  offset  may  be  set  with  the  GOF=  command.  When  the  online  unit  is  being 
"backed up" the BU's attenuator will be set to this value. This value may be different than the 
attenuation value of the online unit to compensate for any gain mismatch between the BU and 
online units. 
 
To calibrate: 
 
1. Identify the unit with the most gain. 
 
2. Calculate the actual error. 
 
3. To compensate for the error, set the GOF= command in the unit having the highest error. 
 
For  example,  if  SSPA  1  has  70  dB  of  gain,  and  BU  SSPA  2  has  72  dB,  send  the  GOF=2.00 
command to the BU SSPA 2 to store these values. 
 
 
 
B–2
Revision 6
MN/HPOD.IOM