Replacing The Non-Return Valve - REMEHA Quinta Pro 30 Installation And Service Manual

Wall-hung gas condensing boilers
Table of Contents

Advertisement

Quinta Pro 30 - 45 - 65 - 90 - 115
7. Checking and maintenance
7.4.2.

Replacing the non-return valve

Replace the nonreturn valve when faulty or when the maintenance kit
contains one. To do this, proceed as follows:
1. Remove the air inlet flue on the venturi.
3
2. Loosen the union on the gas block.
3. Remove the plugs from the fan.
4
4. Remove the plugs from the gas block.
5. Dismantle the fan.
6. Completely remove the fan/mixing elbow unit.
7. Replace the non-return valve located between the mixing elbow
and the fan.
8. To re-assemble, perform the above actions in reverse order.
1
2
5
7
2x
6
8
T002873-C