Replacing the non-return valve

Replace the nonreturn valve when faulty or when the maintenance kit
contains one. To do this, proceed as follows:
1. Remove the air inlet flue on the venturi.
2. Unscrew the top connection on the gas valve unit.
3. Disconnect the connector located under the fan.
4. Release the 2 clips holding the fan/mixing elbow unit in place on
the heat exchanger.
5. Completely remove the fan/mixing elbow unit.
6. Replace the non-return valve located between the mixing elbow
and the fan.
7. To re-assemble, perform the above actions in reverse order.