Cleaning the solenoid
Check the solenoid for any fluid residue and freedom of movement, and that the
pole piece does not stick inside the solenoid. Refer to Figure 6-10.
If residue is present, remove the solenoid screw. Refer to Figure 6-7.
Gently lift the solenoid clear of the body.
On standard solenoids the pole piece can be easily lifted out of the solenoid and
cleaned.
On reverse action solenoids, the circlip must be removed from the pole piece
before removing the pole piece.
Moisten a cotton bud with the cleaning fluid, and remove all the residue. Check
that the solenoid has freedom of movement.
Re-insert the pole piece and spring back into the solenoid and replace the circlip if
one was removed. Lifting the accept gate spring out of the way, re-insert the
solenoid into the divider piece, and re-insert the screw, and tighten with a torque
screwdriver to 47 inch-oz.
28-00486-00
This document contains confidential information which is proprietary to ATI. It may not be disclosed to any unauthorized parties,
and it may not be copied. All rights reserved. © Copyright (ATI) Aristocrat Technologies, Inc. 2002.
Figure 6-10 Solenoid Pole Piece
Coin Chute Assembly
SOLENOID
POLE
PIECE