5.3.2 Output Requirements

Mains GPO

Voltage and Current
+0%, -2% of the input mains voltage at 0 A to 1 A.
Physical Connection
Mains output is via a standard female IEC socket. This output is separately switched
and fused. This fuse is accessible from outside the power supply assembly.

Monitor Output

Voltage and Current
+0%, -2% of the input mains voltage at 0 A to 1.2 A.
Physical Connection
The monitor output is provided via a Molex Minifit Junior 6-pin connector plug
mounted on the metal housing. This output is separately fused, and the fuse is
accessible from outside the power supply assembly.

Generic Output 24 V DC

Provides power to the Backplane for distribution to the Main Board, the I/O Driver
Board, and other low-voltage machine components and peripherals. Maximum
current is specified considering present requirements and allowing for future
flexibility.
Vout = +24 V DC +/-5%
Iout = 0.5 to 15.0 A continuous
Ripple = 200 mVp-p, measured at 0-20 MHz

Fluoro Output 24 V DC

Provides power for the fluorescent lighting system.
Vout = +24 V DC +/-5%
Iout = 0.0 to 2.0 A continuous
Ripple = 200 mVp-p, measured at 0-20 MHz

Output 12 V DC

Provides power for subsidiary equipment. Isolation of 3 kV is provided from this
output to other secondaries and primary.
Vout = +12 V DC +/-5%
Iout = 0.0 to 3.0 A continuous
Ripple = 200 mVp-p, measured at 0-20 MHz