Programming
"^" Button Commands (Cont.)

^BOP

^BOR

^BPP

92
Set the button opacity. The button opacity can be specified as a decimal between 0 - 255,
where zero (0) is invisible and 255 is opaque, or as a HEX code, as used in the color
commands by preceding the HEX code with the # sign. In this case, #00 becomes invisible
and #FF becomes opaque.
If the opacity is set to zero (0), this does not make the button inactive, only invisible.
Syntax:
"'^BOP-<vt addr range>,<button states range>,<button opacity>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
button opacity = 0 (invisible) - 255 (opaque).
Example:
SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,200'"
Example 2:
SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,#C8'"
Both examples set the opacity of the buttons with the variable text range of 500-504 and
510-515 to 200.
Set a border to a specific border style associated with a border value for those
buttons with a defined address range. Refer to theBorder Styles and Programming
Numbers table on page 80 for more information.
Syntax:
"'^BOR-<vt addr range>,<border style name or border value>'"
Variable:
variable text address range = 1 - 4000.
border style name = Refer to the Border Styles and Programming Numbers table on
page 80.
border value = 0 - 41.
Examples:
SEND_COMMAND Panel,"'^BOR-500.504&510.515,10'"
Sets the border by number (#10) to those buttons with the variable text range of 500-504
& 510-515.
SEND_COMMAND Panel,"'^BOR-500.504&510,AMX Elite -M'"
Sets the border by name (AMX Elite) to those buttons with the variable text range of
500-504 & 510-515.
Note: The border style is available through the TPDesign4 border-style drop-down list.
Refer to theTPD4 Border Styles by Name table on page 81 for more information.
Set or clear the protected page flip flag of a button.
Zero clears the flag.
Syntax:
"'^BPP-<vt addr range>,<protected page flip flag value>'"
Variable:
variable text address range = 1 - 4000.
protected page flip flag value range = 0 - 4 (0 clears the flag).
Example:
SEND_COMMAND Panel,"'^BPP-500,1'"
Sets the button to protected page flip flag 1 (sets it to password 1).