AMX Modero NXD-500i Operation/Reference Manual page 72

5" modero wall/flush mount touch panel with intercom
Hide thumbs Also See for Modero NXD-500i:
Table of Contents

Advertisement

Setup Pages and Descriptions
G4 Web Control Settings Page
Back:
Wired icon:
Connection Status icon:
G4 Web Control Settings:
Enable/Enabled:
Network Interface Select: Displays the detected method of communication to the web:
Web Control Name:
Web Control Password:
Web Control Port:
Maximum Number of
Connections:
Current Connection
Count:
G4 Web Control Timeout:
FIG. 53
Sample relationship between G4 Web Control and Manage WebControl Connections window
60
Saves the changes and returns to the previously active touch panel page.
The icon to the left of the Connection Status Icon displays that the current
connection to the Master is Wired (image of three networked computers).
This visual display of the connection status allows the user to have a current
visual update of the panel's connection status regardless of what page is
currently active.
• A Lock only appears on the icon if the panel has established a connection with a
currently secured target Master (requiring a username and password).
Sets the IP communication values for the touch panel and contains:
• The Enable/Enabled button allows you to toggle between the two G4 activation
settings:
- Enable - deactivates the G4 Web Control feature on the panel.
- Enabled - activates the G4 Web Control feature on the panel and allows an
external PC running a VNC client to access the panel after the remaining fields
are configured.
• Wired is used when a direct Ethernet connection is being used for
communication to the web. This is a default setting.
Allows entry of a unique alphanumeric string used as the display name of the
panel within the Manage WebControl Connections window of the new NetLinx
Security browser window.
• This Web Control tab displays a G4 icon alongside the link to the Web Control
Name given to this panel (FIG. 53).
Allows entry of the G4 Authentication session password associated for VNC web
access of this panel.
Allows entry of the VNC Web Server's port value.
• Default value is 5900.
This read-only field displays the maximum number of users that can be
simultaneously connected to the target panel via the Web.
• Default value is 1.
This read-only field displays the current number of users connected to the
target panel via the Web. This value cannot exceed the Maximum number field.
Sets the length of time (in minutes) the panel can remain idle (no cursor
movements) before the session is closed and the user is disconnected.
• Minimum value = 0 minutes (panel never times-out)
• Maximum value = 240 minutes (panel times-out after 240 minutes/4hours)
NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom