Panasonic KX-TAW848 Features Manual page 261

Advanced hybrid & wireless pbx
Hide thumbs Also See for KX-TAW848:
Table of Contents

Advertisement

Q
How do I prevent extension numbers being automatically assigned to a newly
installed card?
A
Change Extension Number Set Mode in the Configuration—Option screen (see
"4.7.8 Option [1-3]") from Automatic to Manual.
Q
How do I prevent newly installed cards automatically being changed to "INS"?
A
Change Status after Card Install in the Configuration—Option screen (see "4.7.8
Option [1-3]") from "In Service (INS)" to "Out of Service (OUS)".
Q
I cannot change an LCO port to INS status.
A
Is the card installed in the appropriate slot?
Is the card installed in the correct slot, but not functioning correctly?
Check the condition of the card.
Is the card itself in INS status?
Set it to INS status.
Is a CO line connected to the appropriate port?
Is the port in FAULT status, even though a CO line is connected?
Run diagnosis on the relevant slot.
Q
How do I change the dialing mode of an analog CO line?
A
From the Configuration—LCO Port screen (see "4.7.9 LCO Port [1-4]"), change the
Dialing Mode setting of the target port to "DTMF" or "Pulse", as required.
Q
How do I set disconnect detection (CPC Detection) for an analog CO line?
A
From the Configuration—LCO Port screen (see "4.7.9 LCO Port [1-4]"), modify the
CPC Signal Detection Time—Outgoing, Incoming setting of the target port.
The required value varies by carrier. Transmission and reception can be set separately.
Q
I cannot open the subwindow for a certain card.
A
First, either install the card, or set the status of a slot to "Pre-Install".
Q
How do I change the extension number of a wired extension?
A
Change the extension number of the target port to the new number, and click Apply.
Then set the port to OUS status, and then back to INS status.
Q
During a conversation, I changed the extension number of a wired extension,
but the display still shows the previous extension number.
A
The extension number will not change while the extension is in use. When the
conversation is finished, set the port to OUS status, and then back to INS status.
Q
How do I change the type of an extension port?
A
Set the port to OUS status. Then, change Type in the Configuration—Extension Port
window (see "4.7.11 Extension Port [1-5]").
Q
I have set the type of an extension port to "DSS Console", but I cannot apply
this setting. (Error E000402)
4.6 Help
Feature Guide