Q
How do I prevent extension numbers being automatically assigned to a newly
installed card?
A
•
Change Extension Number Set Mode in the Configuration—Option screen (see
"4.7.8 Option [1-3]") from Automatic to Manual.
Q
How do I prevent newly installed cards automatically being changed to "INS"?
A
•
Change Status after Card Install in the Configuration—Option screen (see "4.7.8
Option [1-3]") from "In Service (INS)" to "Out of Service (OUS)".
Q
I cannot change an LCO port to INS status.
A
•
Is the card installed in the appropriate slot?
•
Is the card installed in the correct slot, but not functioning correctly?
Check the condition of the card.
•
Is the card itself in INS status?
Set it to INS status.
•
Is a CO line connected to the appropriate port?
•
Is the port in FAULT status, even though a CO line is connected?
Run diagnosis on the relevant slot.
Q
How do I change the dialing mode of an analog CO line?
A
•
From the Configuration—LCO Port screen (see "4.7.9 LCO Port [1-4]"), change the
Dialing Mode setting of the target port to "DTMF" or "Pulse", as required.
Q
How do I set disconnect detection (CPC Detection) for an analog CO line?
A
•
From the Configuration—LCO Port screen (see "4.7.9 LCO Port [1-4]"), modify the
CPC Signal Detection Time—Outgoing, Incoming setting of the target port.
The required value varies by carrier. Transmission and reception can be set separately.
Q
I cannot open the subwindow for a certain card.
A
•
First, either install the card, or set the status of a slot to "Pre-Install".
Q
How do I change the extension number of a wired extension?
A
•
Change the extension number of the target port to the new number, and click Apply.
Then set the port to OUS status, and then back to INS status.
Q
During a conversation, I changed the extension number of a wired extension,
but the display still shows the previous extension number.
A
•
The extension number will not change while the extension is in use. When the
conversation is finished, set the port to OUS status, and then back to INS status.
Q
How do I change the type of an extension port?
A
•
Set the port to OUS status. Then, change Type in the Configuration—Extension Port
window (see "4.7.11 Extension Port [1-5]").
Q
I have set the type of an extension port to "DSS Console", but I cannot apply
this setting. (Error E000402)
4.6 Help
Feature Guide