Henny Penny PFE-591 Operator's Manual page 53

Pressure fryer-electric
Hide thumbs Also See for PFE-591:
Table of Contents

Advertisement

3-16. SPECIAL PROGRAM
MODE (Continued)
403
Type of shortening to be melted - Liquid or Solid (SP-6)
The Melt Cycle can be set to the type of shortening being used.
a. Follow steps 1 and 2 above.
b. Press and release
and "MELT CYCLE SELECT" flashes on the display,
along with "l=LIQ" or "2=SOLID".
c. Press
to toggle from one type to another.
The type of shortening being used in the cooker
determines the amount of heat applied during the Melt
Cycle. If the controls are set to the solid setting, less heat
is applied to the shortening, than if the controls were set
to liquid. Too much heat applied to solid shortening
causes much smoking, and could cause a fire. Match this
setting to the type of shortening being used at the time.
When using solid shortening, it is recommended to melt
the shortening on an outside source before placing
shortening in the frypot. Unless elements are
completely covered in shortening, fire or damage to the
frypot could result.
Idle Mode (SP-7)
A programmed Idle Mode allows the shortening temperature to
drop to a lower temperature when not in use. This saves on the
shortening and utilities.
a. Follow steps 1and 2 above.
b. Press and release
MODE ENABLED?" flashes in the display, along with
"NO" or "YES".
c. Press and release
or vice versa.
d. With "YES" in the display, the Idle Mode is enabled.
Press and release
"IDLE SETPT TEMP" shows in the display, along with
the preset temperature.
Model PFE- 591
5 times. "SP-6"
6 times. "SP-7" and "IDLE
to toggle from NO to YES,
. "SP-7A" and
3-37