Henny Penny PFE-591 Operator's Manual page 39

Pressure fryer-electric
Hide thumbs Also See for PFE-591:
Table of Contents

Advertisement

3-12. CLEANING THE FRYPOT
(Continued)
703
5.
Fill the frypot to the level indicators with hot water.
Add 8 to 10 ounces of fryer cleaner (Henny Penny part
number 12101) to the water and mix thoroughly.
Always wear chemical splash goggles or face shield and
protective rubber gloves when cleaning the frypot as the
cleaning solution is highly alkaline. Avoid splashing or
other contact of the solution with your eyes or skin.
Severe burns and possible blindness will result. Care-
fully read the instructions on the cleaner. If solution
comes in contact with your eyes, rinse thoroughly with
cool water and see a physician immediately.
6.
Turn the COOK/PUMP switch to COOK and enter the
Clean-Out Mode by pressing and holding
OUT?", "1=YES 2=NO" shows in display. Press
start Clean-Out Mode. The fryer displays "*CLEAN-OUT
MODE*" and heats up to a preprogrammed temperature
(195°F (91°C max.) then automatically begins a preset timed
countdown. Use
temperature and to keep cleaning solution from boiling over.
DO NOT CLOSE LID WITH WATER AND/OR
CLEANER IN FRYPOT. WATER UNDER PRES-
SURE BECOMES SUPERHEATED. WHEN LID IS
OPENED, ESCAPING WATER AND STEAM WILL
RESULT IN SEVERE BURNS.
Watch the cleaning solution constantly to make sure it
does not boil over causing damage to controls.
Do not use steel wool, other abrasive cleaners or clean
ers/ sanitizers containing chlorine, bromine, iodine or
ammonia chemicals, as these will deteriorate the stainless
steel material and shorten the life of the unit.
Do not use a water jet (pressure sprayer) to clean
the unit, or component failure could result.
Model PFE- 591
until "CLEAN
, if necessary, to adjust the
to
3-23

Advertisement

Table of Contents
loading