3-16. SPECIAL PROGRAM
MODE (Continued)
3-38
e. Change the idle setpoint temperature, by pressing
f. Press and release
"AUTO-IDLE MINUTES" shows in the display, along
with the preset time.
g. Press
to set the minutes the fryer stays idle
before the Auto-idle is enabled; 60 the maximum, OFF the
minimum. Ex: "30" in the display means, if product is not
cooked in that frypot for 30 minutes, the control automatically
activates the idle setpoint temperature, programmed above.
h. Press and release
MELT EXIT?" shows in display.
i. Press
to toggle from NO to YES, or vice versa. With
"YES" in the display, the fryer automatically enters the Idle Mode
once the Melt Mode is exited.
Filter Tracking Enabled (Sp-8)
The controls can be set to signal the operator when the
shortening needs filtering. The Filter Tracking must be
enabled to program the number of Cook Cycles between
filtering procedures. (See Filter Cycles section 2-2.)
a. Follow steps 1 and 2 above.
b. Press and release
and "FILTER TRACKING ENABLED" flashes on the
display, along with "1,OFF".
c. To enable the filter tracking, press
display from " 1,OFF", to "2,MIXED", to "3,GLOBAL", or
"4SCHED".
The Mixed setting allows the operator to set different amounts
of Cook Cycles, between filters, for each product. If the op-
erator wants to have one setting for all products go to step h.
MIXED
d. If "2,MIXED" is selected, press
the display followed by "SUGGEST FILTER AT ..." and a
value between 75% and 100%. Press and release
the to change this value.
e. Press
and "SP-8B" shows in the display followed
by "LOCKOUT ENABLED?" and "YES" or "NO".
Press and release
Model PFE- 591
. "SP-7B" and
. "SP-7C" and "GO IDLE AT
until "SP-8"
and "SP-8A" shows in
to choose yes or no.
to toggle the
1005