Changing The Filter Envelope - Henny Penny PFE-591 Operator's Manual

Pressure fryer-electric
Hide thumbs Also See for PFE-591:
Table of Contents

Advertisement

3-9. FILTERING INSTRUCTIONS
(Continued)
3-10. CHANGING THE FILTER
ENVELOPE
3-20
7.
Turn COOK/PUMP switch to PUMP.
8.
When all shortening has been pumped into frypot turn
COOK/PUMP switch off.
IF THERE ARE AIR BUBBLES COMING UP IN THE
SHORTENING, IT'S POSSIBLE THAT THE FILTER
CONNECTION AT THE UNION ON THE FILTER
TUBE IS NOT TIGHTENED PROPERLY. IF SO,
TURN OFF THE PUMP AND USE PROTECTIVE
CLOTH OR GLOVE WHEN TIGHTENING THE
UNION. THIS UNION WILL BE HOT AND SEVERE
BURNS COULD RESULT.
The filter envelope should be changed after 10-12 filterings, or
whenever it becomes clogged with crumbs. Proceed as follows:
1.
Move the COOK/PUMP switch to the OFF position.
2.
Remove and empty the condensation drain pan.
3.
Disconnect the filter union and remove the filter drain pan
from beneath the frypot.
Use protective cloth or glove when disconnecting the
filter union or severe burns could result.
If the filter pan is moved while full of shortening, use
care to prevent splashing, or severe burns could result.
4.
Lift the filter screen assembly from the drain pan.
5.
Wipe the shortening and crumbs from the filter drain pan.
Clean the filter drain pan with soap and water. Thoroughly
rinse with hot water.
6.
Unthread the standpipe from the filter screen assembly.
7.
Remove the crumb catcher and clean thoroughly with
hot water.
Model PFE- 591