3-14. PREVENTIVE
MAINTENANCE
Continued)
SAFETY VALVE
3-28
Cleaning Safety Relief Valve-Annually
DO NOT ATTEMPT TO REMOVE SAFETY VALVE
WHILE FRYER IS OPERATING, OR SEVERE BURNS
OR OTHER INJURIES WILL RESULT.
1. Use a wrench to remove pressure gauge.
2. Use a wrench to loosen the valve from the pipe tee, turn
counterclockwise to remove.
Turn the safety relief valve towards the rear of the fryer when
reinstalling the relief valve.
3. Clean the inside of the pipe tee with hot water.
4. Immerse the safety relief valve in a soapy water solution
for 24 hours. Use a 1 to 1 dilution rate. The valve cannot
be disassembled. It is factory preset to open at 14-1/2
pounds of pressure. If it does not open or close, it must
be replaced.
DO NOT DISASSEMBLE OR MODIFY THIS SAFETY
VALVE. TAMPERING WITH THIS VALVE COULD
CAUSE SERIOUS INJURIES AND WILL VOID
AGENCY APPROVALS AND APPLIANCE
WARRANTY.
Model PFE- 591