Information Mode - Henny Penny PFE-591 Operator's Manual

Pressure fryer-electric
Hide thumbs Also See for PFE-591:
Table of Contents

Advertisement

3-17. INFORMATION MODE

3-44
This mode gathers and stores historic information on the fryer and
operator's performance. Press
and "*INFO MODE*" shows on display. Press
to access the steps and press
each step. Information Mode is intended for technical use, but
the operator can view the following information:
1. E-LOG - last 10 errors and time they occurred
2. LAST LOAD - information about the most recent Cook
Cycle, or the cycle presently in progress
3. DAILY STATS - information for the last 7 days.
4. REVIEW USAGE- information accumulated since the
last time this data was manually reset
5. INP A VHDSF M - provides test of fryer inputs
6. OUTP - shows the state of heater and pressure
7. OIL TMP - temperature of shortening
8. CPU TMP - temperature of PC board
9. ANALOG - status of controller's a-to-d converter
Press and hold
time, or after 2 minutes, controls automatically exit back to
normal operation.
1. E-LOG (error code log)
Press
and "1A" (date & time) "*NOW*" shows in
display. This is the present date and time.
Press
and if a error was recorded, "1B" (date, time, and
error code information) shows in display. This is the latest
error code that the controls recorded.
Press
and the next latest error code information can be
seen. Up to 10 error codes (1B to 1K) can be stored in the
E-LOG Section.
Press
to continue to LAST LOAD.
Model PFE- 591
and
at the same time
to view the statistics within
to exit Information Mode at any
or
403

Advertisement

Table of Contents
loading

Table of Contents