3
Determine which fan group needs to be replaced by noting which fans are not operating.
4
Pull up the locking handle (4) on the system fan, then lift the fan group (5) from the fan
cage in the chassis.
Important
Make sure that the arrows on top of the fans indicating airflow point to the
back of the chassis. The fan cable should exit the fan module toward the back of the
chassis.
5
Insert the replacement fan group into the fan cage and press down the locking handle to
secure the fan group in place.
6
Follow the instructions in
To replace the system fan and fan cage assembly:
Important
Both system fan cages are replaced in a similar manner.
1
Follow the instructions in
that you turn off the server, then unplug the power cord(s) and all other cables connected
to the server.
2
Follow the instructions in
3
Remove the fan duct by lifting it out of the chassis.
www.gateway.com
"Closing the server case" on page
"Preventing static electricity discharge" on page
"Opening the server case" on page
32.
30. Make sure
31.
45