SECTION 12—BATTERIES AND CHARGER
4. Cut the tie-wrap that secure each the battery terminal cap in place.
5. Slide terminal cap(s) UP on the battery cable(s).
6. Disconnect battery cable(s) from battery(ies) terminal(s)/post(s):
A. POSITIVE (+) RED battery cable from the POSITIVE (+) battery terminal/post.
B. NEGATIVE (-) BLACK battery cable from NEGATIVE (-) battery terminal/post.
To BLACK Battery
Connector
POSITIVE (+)
Terminal Cap
U1
Battery
Locknut
RED Battery Cable
NOTE: Only battery cable and terminal cap shown. Both caps install in the same manner.
NOTE: DO NOT remove fuse or mounting hardware from the POSITIVE (+) RED battery
cable/mounting screw.
FIGURE 12.5 Connecting/Disconnecting the Battery Cables on the Zoom 400

Replacing the Charger

Zoom 300

NOTE: For this procedure, refer to FIGURE 12.6 and FIGURE 12.2.
1. Place the powered scooter in a well ventilated area.
Work should be performed in an area without risking damage to carpeting or floor
covering.
2. Turn power off and remove the key from the ignition.
3. Remove the seat. Refer to Removing/Installing the Seat on page 19.
Zoom 300 and Zoom 400
NEGATIVE (-)
Terminal Cap
NEGATIVE (-)
Battery
Terminal
Locknut
BLACK
Battery
Cable
POSITIVE (+)
Battery Terminal
with Bracket
CAUTION
92
DETAIL "A" - TERMINAL CAPS
TIE-WRAPS
Battery Handle
U1 Battery
Battery
Terminal Caps
Tie-Wraps
Part No 1122167