Keypads/Sense Trigger Inputs - Elan System12 Installation Manual And User's Manual

S series multi-room a/v controller
Hide thumbs Also See for System12:
Table of Contents

Advertisement

SYSTEM12
INSTALLATION MANUAL
Connections When Not Using a PS12
Keypad Connections
ELAN keypads require IR, RS-485+, RS-485-, 12 Volts DC, and Ground to function.
Make these connections as shown below. Multiple keypads in the same zone
require parallel connections. For simplicity, all pins can be connected straight
through.
S12 to Keypad Connections (No PS12)
S12
ELAN
C45P
Sense Trigger Input Connections
Information from ELAN™SENSE Sensors connected
to the S12's Sense Trigger Inputs is used to trigger
events that have been programmed into VIA!
panels.
To connect ELANSense sensors directly to the S12,
simply plug the 3.5 mm stereo interconnect cable of
the Sensor into the desired Sense Trigger Input.
ELAN™SENSE Sensor to S12 Sense Trigger Inputs
Page 32
(continued)
Butt splice
or equivalent
Blue
White/Blue
Orange
White/Orange
White/Orange (485+)
Green
White/Green
White/Green (+12V)
Brown
White/Brown
Standard ELAN RJ-45 Pin-Out
PIN # COLOR CODE
TAB
CABLE
Touch
®
AUDIO SENSOR
E L A N
Blue
White/Blue (IR)
Orange
Green (485-)
Brown (GND)
White/Brown
1
BLUE
2
WHITE/BLUE
3
ORANGE
4
WHITE/ORANGE
5
GREEN
6
WHITE/GREEN
7
BROWN
8
WHITE/BROWN
If long runs are required, the 3.5 mm stereo intercon-
nect cable must be cut off and the cable extended
using Cat-5.
Utilize VIA!
Tools setup software to create IR or serial
®
command strings for automated functions. See
VIA!TOOLS Help for additional information about pro-
gramming Sense Triggers.
S12
© ELAN Home Systems 2004 • All rights reserved.
H O M E
S Y S T E M S
ELAN
Keypad
ELAN
C45P

Hide quick links:

Advertisement

Table of Contents
loading