XEROX DOCUPRINT 180 LPS MESSAGE GUIDE
Invalid response for BTEXT RSQ sequence check enablement
parameter.
The sequence check parameter is incorrectly specified.
Action
Check JSL or DJDE in the job stream to ensure that all BTEXT RSQ
keywords and parameters are correct.
Invalid response for BTEXT SEQ page sequence number
parameter.
The page sequence number parameter is incorrectly specified.
Action
Check JSL or DJDE in the job stream to ensure that all BTEXT SEQ
keywords and parameters are correct.
IP Header record not read while completing Audit Log.
The in-process file is corrupted and does not contain a header record
for the report that is being audited.
Action
If the problem persists, call Xerox Customer Service.
Key not found reading in-process file for completion copy.
An expected key value in the in-process file was not found while
copying records from the file.
Action
If the problem persists, call Xerox Customer Service.
Key not found reading in-process file for deletion.
An expected key value in the in-process file was not found while
deleting records from the file.
Action
If the problem persists, call Xerox Customer Service.
Key value modified by another application during Get Next/
Previous.
TBD
Action
If the problem persists, call Xerox Customer Service.
Log xxx cannot be created.
The console log cannot be saved to the floppy diskette.
Action
If problem persists, contact your systems specialist or Xerox
Customer Service.
Log xxx does not exist.
The requested console log file name does not exist.
Action
Try entering another log name.
XEROX DOCUPRINT 180 LPS ADDITIONAL MESSAGES