2
Insert the bottom of the waste toner
bottle
into its installation position in
the printer.
3
Push the top of the waste toner bottle
into position until it is firmly seated.
4
Close the printer's front door.
If the waste toner bottle is not
correctly installed or the transfer belt
release lever is at its top position
(11 o'clock), the front door cannot be
closed.
The printer must complete a 305-second calibration cycle after any
consumable has been replaced. If you open the door before the
display reads
repeats the calibration cycle.

Replacing the OPC Drum Cartridge

When the OPC drum is worn out, the message REPLACE OPC DRUM
appears. Printing can continue even after this message appears; however,
since print quality is reduced, the OPC drum cartridge should replaced
immediately.
The OPC drum life is directly related to the number of rotations of the
drum. Longest drum life is achieved with continuous printing.
Intermittent printing with small job sizes requires cleaning rotations
before and after each job, and impacts OPC life.
Removing the Used OPC Drum Cartridge
1
With the front door open, rotate the
transfer belt unit release lever
clockwise to the top (11 o'clock)
position.
This raises the transfer belt unit.