IMPORTANT: All steps as outlined in „PREPARE EXISTING FIREPLACE‟ must be completed before continuing with this installation.

APPROVED VENTING

Kozy Heat #815-CL Co-Linear Vent System. Follow instructions on pages 14-16.
Kozy Heat #815-CA Co-Axial Vent System. Follow instructions on pages 17-18.
Selkirk, ICC, American Metals, Security. Follow instructions included from vent pipe
manufacturer as well as venting requirements as outlined in this installation manual.

AIR DUCT REMOVAL

Remove air duct by lifting up and off top of insert. Follow instructions below and on
following pages for vent system attachment to air duct.
#911XL-MSP MASONRY SIDE PANEL INSTALLATION (OPTIONAL)
IMPORTANT: For use when insert is installed in an existing masonry opening.
This kit must be attached to air duct (manifold) prior to vent system
connection.
This kit includes: (1)
Right side panel
(1)
Left side panel
(12) Sheet metal screws
NOTE: If air duct and masonry side panels are not placed „outside‟ flanges at
insert bottom, a rattling noise may occur when fan is in operation.
1.
If air duct on insert is not positioned outside flange at bottom, remove and
reposition.
2.
Position each side panel outside the flanges on insert bottom, aligning (2) holes in
top and (2) holes in back of masonry side panels with corresponding holes in air
duct. Secure with screws included.
This installation will be continued at a later point.
RESTRICTOR INSTALLATION
Each installation is unique and affected by various factors including venting configuration, altitude and climate. Therefore, after fireplace
insert installation is complete, a restrictor may be required or may need to be removed or modified.
Page 41 has information on restrictor recommendations depending on burner flame appearance and instructions on installation after venting
is completed.
IMPORTANT: Do not install if venting configuration is at minimum requirements.
Large Restrictor
Remove tab (s) to create
small restrictor
Figure 13b

INSTALLATION

Bend tabs to approx. 80 degree
angles to create tension to hold
itself in place when installed.
PAGE 13
Air Duct
Figure 13a
Masonry side panels and air duct must be
Figure 13a
positioned outside flange at bottom of insert
Slide restrictor into exhaust pipe with tabs
pointing toward you.