Installation; Approved Venting; Air Duct Removal; 9Xl-Msp Masonry Side Panel Installation (Optional) - kozy heat 911XL Installation Manual

Table of Contents

Advertisement

ATTENTION
All steps as outlined in 'PREPARE EXISTING FIREPLACE' must be completed before continuing with this installation.

APPROVED VENTING

Kozy Heat #815-CL Co-Linear Vent System. Follow instructions on pages 10-11.
Selkirk, ICC, American Metals, Security. Follow instructions included from vent pipe manufacturer as well as venting requirements as
outlined in this installation manual.

AIR DUCT REMOVAL

Remove air duct by lifting up and off top of insert. Follow instructions below and on
following pages for vent system attachment to air duct.

#9XL-MSP MASONRY SIDE PANEL INSTALLATION (OPTIONAL)

For use when insert is installed in an existing masonry opening. This kit
IMPORTANT
must be attached to air duct (manifold) prior to vent system connection.
This kit includes: (1)
Right side panel
(1)
Left side panel
(12) Sheet metal screws
If air duct and masonry side panels are not placed outside flanges at
NOTE
insert bottom, a rattling noise may occur when fan is in operation.
1.
If air duct on insert is not positioned outside flange at bottom, remove and
reposition.
2.
Position each side panel outside the flanges on insert bottom, aligning (2) holes in
top and (2) holes in back of masonry side panels with corresponding holes in air
duct. Secure with screws included.
This installation will be continued at a later point.
RESTRICTOR INSTALLATION
IMPORTANT
Do not install if venting configuration is at minimum requirements.
Each installation is unique and affected by various factors including venting configuration, altitude and climate. Therefore, after fireplace
insert installation is complete, a restrictor may be required or may need to be removed or modified.
Page 18 has information on restrictor recommendations depending on burner flame appearance and instructions on installation after venting
is completed.
Large Restrictor
Re move ta b (s ) to
create small restrictor
Figure 9c

INSTALLATION

Bend tabs to approx. 80 degree
angles to create tension to hold
i ts e l f i n pl a c e w he n i ns ta l l e d.
9
Air Duct
Figure 9a
Masonry side panels and air duct positioned
outside flange at bottom of insert.
Figure 9b
Slide restrictor into exhaust pipe on top of fireplace
with tabs pointing towards you prior to attaching
venting.

Advertisement

Table of Contents
loading

This manual is also suitable for:

911xl-mv911xl-rad911xl-ipi

Table of Contents