Stand-Off Assembly And Installation - kozy heat Nordik 48 DV Installation And Operation Manual

Table of Contents

Advertisement

3.5 Stand-Off Assembly and Installation

WARNING: The top stand-offs provide the
8" (203mm) minimum clearance to the header. Use
only non-combustible material in this area for the
entire width of the fireplace. DO NOT use wood,
sheetrock, et cetera, in this zone.
Top stand-off brackets must be formed and attached
prior to positioning fireplace into framed opening.
Note: If installing trim kit assembly #NK48-FTK, please
refer to Section 5.2 Finishing Trim Kit Assembly be-
fore installing stand-offs.
Note: If installing KZK-045 complete the necessary
preparation work before assembling the stand-off
assembly.
Installation:
1. Remove and save (2) screws securing stand-off
heat shields and stand-off brackets on top of the
fireplace.
2. Form each top stand-off bracket by bending at
perforations, as shown.
3. Align the holes in the formed top stand-offs with
the holes in the fireplace top. Secure with the (2)
screws previously removed along with (2) screws
located on top of the fireplace.
4. Form stand-off heat shields as shown. The flange
will face up and to the back of the fireplace.
5. Align the in the stand-off heat shields with the
holes in the top stand-off brackets Secure with
(8) screws provided in the fireplace components
packet.
Hussong Mfg. Co, Inc.
NDK-48-DV - PFS Report No. 23-196
Figure 3.1 - Stand-Off Installation
12
Starting Serial Number: 24 N48DV00001 04
Rev. 1 - November 2023

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ndk-48-dv

Table of Contents