4.3 Attach Heat Duct to Fireplace

1.
Bend the tabs on fireplace top up. With circulation holes facing
down, use (3) screws to fasten the tabs to the duct collar.
2.
Secure the flexible pipe to the duct collar. Verify screws penetrate
both the flexible pipe and the duct collar.
3.
Do not cover circulation holes on the duct pipe.
4.
Position the fireplace in the desired location.
Figure 4.2
4.4 Install Register Mounting
Frame and Junction Box
1.
The register mounting frame and the fan housing are designed
to fit between 2" x 4" stud walls, 16 in (406mm) on center.
Additional framing is required if larger opening exists.
2.
Locate and mark the position of the register.
3.
Insert the register mounting bracket into the 16 in (406 mm)
opening.
4.
Level and adjust the mounting bracket. The sides of the bracket
should be flush with the front of the framing studs, and the front
of the bracket should protrude ½ in from the studs to allow for
½" sheetrock installation.
5.
Secure the mounting bracket to framing with the provided (4)
sheetrock screws.
6.
Install the junction box on the wall at desired location. The
junction box is used to house the speed control assembly, which
controls fan speed and operation.
WHITE
OR
BLACK
BLACK
Figure 4.5
18 #970 HEAT DUCT KIT
SPEED
CONTROL
WHITE
OR
BLACK
BLACK
WHITE
GROUND
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Figure 4.3

4.5 Install and Wire Fan Assembly

1.
Attach, but do not tighten, flange nuts to the mounting studs on
the back of the register mounting bracket.
2.
Align (3) slots on the fan assembly to studs, then slide the fan
into position. Tighten the flange nuts to secure.
3.
Slide the included fan wire connectors into the fan terminals.
4.
Properly wire the 110 VAC wire to the hot and neutral fan wires,
and the speed control wires, with provided wire nuts.
5.
Run 110 VAC to fan speed control, then from the fan speed
control through the romex connector (on the register bracket).
6.
Secure grounding wire to the grounding screw installed in
register mounting bracket.
Figure 4.4
GROUNDING SCREW
ROMEX CONNECTOR
Fan must be properly grounded.
Grounding
Screw
BLACK
WHITE
#SLA-42S R.7 December 2018