Fan Direct Wire Installation - kozy heat Jackson 911XXL Installation And Operation Manual

Hide thumbs Also See for Jackson 911XXL:
Table of Contents

Advertisement

FAN DIRECT WIRE INSTALLATION

DIRECT WIRE CONNECTION MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN.
911XXL: This fireplace insert comes complete with a fan and thermostatic control switch already installed. A speed control, receptacle,
and fan cord have been installed, wired and mounted in a removable electrical box panel on right side of fireplace. If wiring to
pre-installed electrical box is desired, wiring should be run prior to permanently setting insert in place and connecting vent system.
911XXL-RAD: A speed control, receptacle, and fan cord have been installed, wired and mounted in an electrical box panel included with
fan kit. If hardwiring to electrical box is desired, wiring should be run prior to permanently setting insert in place and
connecting vent system.
NOTE: If wiring to pre-installed electrical box is desired, wiring should be run prior to permanently setting insert in place and
connecting vent system.
If this fireplace insert is being installed in minimum opening dimensions, wiring may need to be completed after fireplace insert
is set in place.
WARNING: This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not cut or remove grounding prong from this plug. Do not allow
any excess fan cord to touch fireplace.
NOTE: Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly. Refer to local electrical codes for
specific requirements in your area.
DIRECT WIRE INSTALLATION: The cord must be removed and wiring disassembled. Insert 110V-120V wiring (with ground) through
110V-120V
60Hz
Figure 10a
1.
911XXL: Remove speed control / receptacle assembly from right side of insert floor.
2.
911XXL / 91XL-RAD: Remove (2) screws securing speed control / receptacle to expose wiring.
3.
Remove existing cord and insert 110V-120V wiring (with ground) through romex connector, wiring to speed control / receptacle assem-
bly, matching black (hot), white (neutral), and green (ground) wire to the corresponding wires on speed control / receptacle assembly.
NOTE: The (3) wire nuts obtained when removing existing cord may be used for this purpose.
4.
Secure speed control / receptacle assembly into the electrical box with (2) screws provided.
5.
Attach electrical box to insert floor with nut.
NOTE: A mounting stud has been provided on right side of fireplace to reposition speed control / receptacle assembly if desired.
Refer to page 17 for instructions on completing fan wiring after insert has been installed.
This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Codes, CSA C22.1
romex connector and wire to box cover assembly, matching black, white & green (ground) wires to
corresponding wires on electrical box cover assembly.
Electrical Box
Speed Control /
Receptacle Assembly
PAGE 10
Temperature Switch:
Magnetically attaches to bottom
of firebox.