FAN DIRECT WIRE INSTALLATION

DIRECT WIRE CONNECTION MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN.
911-RAD: Optional: #911-028 fan kit
#600-083C speed control, receptacle assembly
911: This fireplace insert comes complete with a fan and thermostatic control switch already installed. A speed control, receptacle,
and power cord have been installed, wired and mounted in a removable electrical box panel on right side of fireplace.
911-IPI: This fireplace insert comes complete with a fan kit already installed. A double receptacle and power cord have been installed,
wired and mounted in a removable electrical box panel on right side of fireplace.
NOTE: If wiring to pre-installed electrical box is desired, wiring should be run prior to permanently setting insert in place and
connecting vent system.
If this fireplace insert is being installed in minimum opening dimensions, wiring may need to be completed after fireplace insert
is set in place.
WARNING: This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not cut or remove grounding prong from this plug. Do not allow
any excess fan cord to touch fireplace.
NOTE: Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly. Refer to local electrical codes for
specific requirements in your area.
DIRECT WIRE INSTALLATION: The cord must be removed and wiring disassembled. Insert 110V-120V wiring (with ground) through
911-IPI WIRING SCHEMATIC
Figure 10a
DIRECT WIRE INSTALLATION
1. 911: Loosen (but do not remove) screw securing removable access panel (with electrical box & romex connector installed) from
right side of fireplace. Remove access panel.
2. 911 / 911-RAD / 911-IPI: Remove box cover assembly to expose wiring.
3. Remove existing cord and insert 110V-120V wiring (with ground) through romex connector, wiring to box cover assembly, matching
black (hot), white (neutral), and green (ground) wires to corresponding wires on box cover assembly using (3) wire nuts obtained when
removing existing cord.
4. Reattach box cover assembly with (2) screws provided.
Refer to page 19 for instructions on completing fan wiring after insert has been installed.
This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Codes, CSA C22.1
romex connector and wire to box cover assembly, matching black, white & green (ground) wires to
corresponding wires on electrical box cover assembly.
PAGE 10
911 WIRING SCHEMATIC
Figure 10b