Basic software procedures
Ê Select Server Configuration Manager.
Ê Check the box for rack model and save the setting by clicking Save.
Using the ServerView Maintenance Tools
On Windows-based servers with ServerView agents installed, proceed as
follows:
Ê Click Start, point to All Programs, and then point to Fujitsu - ServerView Suite -
Agents - Maintenance Tools.
Ê In the Maintenance Tools menu pane, click the Chassis Model Configuration tab.
Ê Under Convert to click the Rack Model button.
Ê Click Exit to close the Maintenance Tools menu pane.
I
For more detailed information on installing ServerView agents, refer to
the "ServerView Operations Manager - Installation ServerView Agents
for Windows" user guide.

5.2.20 Performing a fan test after replacing a defective fan

After replacing a defective system fan or power supply unit containing a
defective fan, the fan error indicators will stay lit until the next fan test. By
default, a fan test is automatically started every 24 hours. The first automatic fan
test being performed after replacing a fan will turn off the fan error indicator.
If you want to start the fan test manually, you can do so by following the
description below:
Executing the fan test via the iRMC Web interface
Ê Log into the iRMC web interface.
Ê Under Sensors select Fans.
Ê Select the replaced fan in the system fans group and click Start Fan Test.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
Executing the fan test via ServerView Operations Manager
Ê Open the ServerView Operations Manager and log in.
96
Upgrade and Maintenance Manual
TX140 S2