Star Micronics TSP600 Series Programmer's Manual page 33

Hide thumbs Also See for TSP600 Series:
Table of Contents

Advertisement

Define logo data
FUNCTION
CODE
<ESC> <FS> "q" n [x11 x12 y11 y12 d [k1]] 1... [xn1 xn2 yn1
yn2 d[kn]]n
1B
HEX
yn2 d[kn]]n
Define the logo data specified by n.
REMARKS
n
1 n 255
[xn1 xn2 yn1 yn2 d[kn]]n
xn1, xn2
yn1, yn2
d[kn]
Note) This command is specified at the beginning of the line.
This command cancels all logo images that have already been
defined by this command. The printer cannot redefine only one of
several data definitions previously defined. Is this case, all data
needs to be sent again.
Total defined data area is 480K bytes for TSP800 (256K bytes for
TSP600 / 700).
If there is not enough empty area that was specified with the
parameter, or if any mistake in the parameter is turned out, the
processing of this command is terminated. (However, the logo
images whose definition had been completed before termination
are effective.)
When the processing of this command is completed, or terminated,
the printer will be initialized.
Form the beginning of processing of this command till the finish
of hardware reset, error process, mechanical operations and status
processes cannot be performed.
1C
71
n [x11 x12 y11 y12 d [k1]] 1... [xn1 xn2 yn1
The number of logo images to define is specified.
Parameter and data are specified according to the number
specified by n.
1 (xn1 + xn2 256) 1023
Horizontal size of the logo image is specified as (xn1 + xn2
256)
8 dots.
1 (yn1 + yn2 256) 288
Vertical size of the logo image is specified as (yn1 + yn2
256) 8 dots.
kn = (xn1 + xn2
Logo data is specified.
– 30 –
256) (yn1 + yn2 256) 8