Oce VarioStream 7000 SINGLE Operating Manual page 282

Table of Contents

Advertisement

7.3.4.5 Replacing charge corotrons (torn wire)
Proceed as follows:
2.
Caution
When removing the charge corotron cartridge, the nipple on the corotron wire may
fall into the developer station without you noticing. If printing then continues, the
developer station can be irreparably damaged.
When changing the faulty charge corotron cartridge, always check if the nipple is still
on the corotron wire. If the nipple is missing, search for and find it.
3.
Check whether the nipple is still in on the corotron wire. If the nipple is missing,
search for it. To do this, pull out the developer station (see section 6.7 Cleaning the
developer station, page 203) and search the developer station and the entire area
around it. If no nipple is found, remove the photoconductor drum and search this
area.
Install new charge corotron
Important
Observe the safety directives before replacing corotrons (see section 7.3.4 Replacing
corotrons, page 269).
282
Remove corotron cartridges
individually.
A29246-X20-X-4-7680 / fa703.fm
2 of 2

Advertisement

Table of Contents
loading

Table of Contents