Proceed as follows:
9.
Caution
There can be a high build-up of static charge when vacuuming the toner spill.
Always use an industrial vacuum cleaner with a grounded suction tube, rubber
nozzle and filter set for fine dust. For larger quantities of toner spill (e. g. full bottle),
the industrial vacuum cleaner must be explosion-proof.
10.
11. Put on heat protection gloves (if you are not already wearing them).
A29246-X20-X-4-7680 / fa603.fm
6.5 Cleaning the fuser station
Swing the active filter unit back by the
handle until it reaches the stop point.
Vacuum the cleaning belt of dirt below
the contact surface with the fuser
roller.
3 of 8
193