Toshiba PROSEC T1 User Manual page 140

Programmable controller
Hide thumbs Also See for PROSEC T1:
Table of Contents

Advertisement

7. Instructions
Transitional contact (Falling edge)
Expression
Input
Output
Function
When the input at last scan is ON and the input at this scan is OFF, the output is turned ON.
This instruction is used to detect the input changing from ON to OFF.
Execution condition
Input
OFF
When the input state at last scan is OFF
When the input state at last scan is ON
ON
Regardless of the input state at last scan
Operand
No operand is required.
Example
Coil Y022 comes ON for only 1 scan when the device X000 comes OFF.
X000
Y022
Note
· In case of T1, the maximum usable number in a program is 512. (
· In case of T1S, the maximum usable number in a program is 2048.
(
P
138
T1/T1S User's Manual
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Operation
1 scan time
total)
N
(P)
(N)
Output
OFF
ON
OFF
1 scan time
6F3B0250
and
total)