The followings are examples of index modifications.
RW10
D0201×D0200
!
CAUTION
NOTE
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
I
J
Be careful that the registers do not exceed the address range by the index
modification. The address range is not checked by the T1/T1S.
Substitutions of values into index registers and index modifications can be
used any times in a program. Normally, the program will be easier to see if a
value substitution into an index register is positioned immediately before the
index modification.
6. Programming Information
When I = 0, it designates RW10.
When I = 1, it designates RW11.
When I = -1, it designates RW09.
When I = 10, it designates RW20.
When I = -10, it designates RW00.
When J = 0, it designates D0201×D0200.
When J = 1, it designates D0202×D0201.
When J = 2, it designates D0203×D0202.
When J = -1, it designates D0200×D0199.
When J = -2, it designates D0199×D0198.