Setting Limit Overrun

CAL
RU
This Setting is a matter of trial and Error
1) If operator is in RUN mode, press CAL/RUN
2) Press SCROLL
until display reads "LIMIT OVERRUN>#" where # is the
CROLL
increment of travel beyond the CLOSE Limit ranging from 0 to 9. Zero
turns off the Overrun function and the door stops at the DOWN Limit.
Nine is the maximum distance the door will travel passed the limit. This
function is used to insure a good seal at the bottom of the door.
Figure 9.
3) Press SET/CLEAR
SET
key to toggle between 0 and 9—one digit at a time.
CLEAR
4) Pick a value and operate the door. Adjust as necessary.
5) Press a SCROLL
key to shift to a new function and lock in the setting.
SCROLL
6) Press CAL/RUN
to return to run mode.
CAL
RUN
NOTE: The actual distance that the Overrun function covers is variable depending
R
on model of operator and size of the door (nominally about 2 inches of travel).
WARNING:
The Limit Overrun function will override external
reversing devices, including photocells and sensing or reversing edges.
Therefore, any externally connected devices will be disabled during that
portion of door travel which is controlled by the Limit Overrun function.
GCL-GCX
Counter Door Operator
CAL
to enter calibration mode.
RUN
EN
S ROLL
R
SET
CLO E
www.geniecompany.com
LIMIT OVERRUN #
Figure 9
CAL
RUN
OPEN
CLOSE
STOP
SET
SCROLL
CLEAR
SCROLL
08-12
6.4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents