On-screen error message
0B71 System temperature out
of Range
0B80 BMC Memory Test Failed
0B81 BMC Firmware Code
Area CRC check failed
0B82 BMC core Hardware
failure
0B83 BMC IBF or OBF check
failed
0B90 BMC Platform
Information Area
corrupted
0B91 BMC update firmware
corrupted
0B92 Internal Use Area of
BMC FRU corrupted
0B93 BMC SDR Repository
empty
0B94 IPMB signal lines do not
respond
0B95 BMC FRU device failure
0B96 BMC SDR Repository
failure
0B97 BMC SEL device failure
0B98 BMC SEL Overflow
0BB0 SMBIOS - SROM data
read error
0BB1 SMBIOS - SROM data
checksum bad
0BD0 1st SMBus device
address not
acknowledged
0BD1 1st SMBus device Error
detected
0BD2 1st SMBus timeout
0BD3 2nd SMBus device
address not
acknowledged
0BD4 2nd SMBus device Error
detected
0BD5 2nd SMBus timeout
0BD6 3rd SMBus device
address not
acknowledged
Cause
Ambient temperature is out
of range.
Fan is faulty.
CPU/PCI module board is
faulty.
BMC is faulty.
BMC is faulty.
SROM is faulty.
BMC is faulty.
BMC is faulty.
SEL (System Event Log)
overflowed.
SROM is faulty.
Back panel board is faulty.
Board is faulty.
Troubleshooting
Action
Check the setting in SETUP
Clean the fan.
Replace the fan.
Replace the CPU/PCI
module board.
Replace the PCI module
board.
Replace the PCI module
board.
Replace the PCI module
board.
Erase the unnecessary SEL.
Replace the back panel board.
Check cable connection.
Replace the board.
7-17