NAME
setdualpowerfeed - set dual power feed mode
SYNOPSIS
setdualpowerfeed -s key
setdualpowerfeed -h
DESCRIPTION
The setdualpowerfeed(8) command specifies dual power feed mode in the
system.
Note – The ability to enable and disable dual power feed is available on M3000/
M4000/M5000 servers only. However, dual power feed mode cannot be used with
100V power on M4000/M5000 servers. When the optional power cabinet for dual
power feed is connected on M8000/M9000 servers, it automatically configures dual
power feed mode. For details about the setting of dual power feed, see the
Installation Guide for your server.
To enable the dual power feed mode, you need to execute the rebootxscf(8)
command or turn off and on the input power.
To disable the dual power feed mode, you need to turn off and on the input power.
You must have platadm or fieldeng privileges to run this command.
Privileges
Refer to setprivileges(8) for more information.
OPTIONS
The following options are supported:
-h
-s key
EXTENDED
The state of the current dual power feed mode can be checked by using the
DESCRIPTION
showdualpowerfeed(8) command.
EXAMPLES
EXAMPLE 1
Displays usage statement. When used with other options or
operands, an error occurs.
Sets dual power feed mode in the system. Either of the following
can be specified for key:
enable
disable
Disables dual power feed mode in the system. Before rebooting the system, a
message is displayed.
setdualpowerfeed -s disable
XSCF>
enable -> disable
NOTE: Dual power feed will be disabled the next time the platform is powered
on.
Enables the dual power feed mode.
Disables dual power feed mode.