Setdualpowerfeed - Fujitsu SPARC Enterprise M3000 Xscf Reference Manual

Xscf control package (xcp) 109x
Hide thumbs Also See for SPARC Enterprise M3000:
Table of Contents

Advertisement

NAME
setdualpowerfeed - set dual power feed mode
SYNOPSIS
setdualpowerfeed -s key
setdualpowerfeed -h
DESCRIPTION
The setdualpowerfeed(8) command specifies dual power feed mode in the
system.
The setdualpowerfeed(8) command is available on the M3000/M4000/M5000
servers only. On the M8000/M9000 servers, when the power cabinet for dual power
feed connected, it automatically configures the dual power feed mode.
To enable the dual power feed mode, you need to execute the rebootxscf(8)
command or turn off and on the input power.
To disable the dual power feed mode, you need to turn off and on the input power.
You must have platadm or fieldeng privileges to run this command.
Privileges
Refer to setprivileges(8) for more information.
The following options are supported:
OPTIONS
-h
-s key
EXTENDED
The state of the current dual power feed mode can be checked by using the
DESCRIPTION
showdualpowerfeed(8) command.
EXAMPLES
EXAMPLE 1
EXAMPLE 2
Displays usage statement. When used with other options or
operands, an error occurs.
Sets dual power feed mode in the system. Either of the following
can be specified for key:
enable
disable
Disables dual power feed mode in the system. Before rebooting the system, a
message is displayed.
setdualpowerfeed -s disable
XSCF>
enable -> disable
NOTE: Dual power feed will be disabled the next time the platform is powered
on.
Enables dual power feed mode in the system. Before rebooting the system, a
Enables the dual power feed mode.
Disables dual power feed mode.
System Administration

setdualpowerfeed(8)

187

Advertisement

Table of Contents
loading

Table of Contents