Running computer
Hide thumbs Also See for S625X:
Table of Contents

Advertisement

2. Remove the battery cover from the connector, lift the battery from the
niche and replace it with a new battery.
3. Remove the sealing ring of the battery cover and replace it with a new
ring.
4. Place the negative (-) side of the battery against the connector and the
positive (+) side against the cover.
5. Put the battery in the connector's niche and put the cover on so that the
arrow points to the OPEN position. Make sure that the cover's sealing
ring is placed correctly in its groove.
6. Gently press the cover deep enough so that its exterior surface is on the
same level as the connector's surface.
7. Turn the cover clockwise so that the arrow on the cover turns from OPEN
to CLOSE. Make sure that the cover is closed properly!
In order to ensure the maximum life span of the connector's battery
cover, open it only when you need to change the battery. We
recommend that you change the sealing ring of the battery cover every
time you change the battery. You can get the sealing ring/battery kits
from well-equipped Polar retailers and authorized Polar Services. In the
USA and Canada: Additional sealing rings are available from an
authorized Polar Service Center only.
S1 foot pod
The battery of the foot pod needs to be replaced if the green light on the
foot pod turns red or there is no light at all when you press and hold the
red button on the foot pod. Check the easy start section for replacing the
battery.