The Gateway of Company B is 192.168.20.1. The settings of company B are as the following.
Step 1. Enter the default IP of Company B's Multi-Homing Security Gateway, 192.168.20.1. Click VPN in the
menu bar on the left hand side, and then select the sub-select IPSec Autokey. Click Add.
Step 2. Enter the VPN name, VPN_B in IPSec Autokey window, and choose From Source to be Internal. Fill
the subnet IP, 192.168.20.0 and subnet mask, 255.255.255.0.
Step 3. In To Destination table, choose Remote Gateway-Fixed IP, enter the IP desired to be connected,
company A's subnet IP and mask, 192.168.10.0 and 255.255.255.0 respectively.
Step 4. In Authentication Method Table, choose Preshare and enter the Preshared Key. (The max length is
100 bits.)
Step 5. In Encapsulation -> ISAKMP Algorithm, choose 3DES for ENC Algorithm and MD5 for AUTH
Algorithm. And select Group 1 to connect.
Step 6. Choose GRE/ IPSec and enter GRE Source IP, 192.168.50.200 and GRE Remote IP,
192.168.50.100.
Note. The Source IP and Remote IP should be in the same C Class.