Agilent MOI for MHL Cables Compliance Tests
9. Press
Analysis
> Fixture Simulator > De-Embedding SnP > De-Embedding SnP
and turn it ON.
The following 2-port fixture compensation is applied to CBUS Insertion Loss
measurement.
1. Press
Analysis
> Fixture Simulator and turn it ON.
2. Press
Analysis
> Fixture Simulator > De-Embedding > Select Port > 1.
3. Press
Analysis
> Fixture Simulator > De-Embedding > User File and specify a
2-port de-embedding file (*.s2p) for the Source fixture.
4. Press
Analysis
> Fixture Simulator > De-Embedding > Select Type to set to User.
5. Press
Analysis
> Fixture Simulator > De-Embedding > Select Port > 2.
6. Press
Analysis
> Fixture Simulator > De-Embedding > User File and specify a
2-port de-embedding file (*.s2p) for the Sink fixture.
7. Press
Analysis
> Fixture Simulator > De-Embedding > Select Type to set to User.
Note that the fixture compensation is not performed for CBUS Line Capacitance
measurement.
14