Cbus Insertion Loss; Far-End Crosstalk; Cbus Line Capacitance - Agilent Technologies E5071C Compliance Tests

Mhl (mobile high-definition link) specification version 2.0; agilent method of implementation (moi) for mhl cables; ena option tdr
Hide thumbs Also See for E5071C:
Table of Contents

Advertisement

Agilent MOI for MHL Cables Compliance Tests
7. Press
Analysis
> Fixture Simulator > BalUn and turn it ON
8. Press
Analysis
> Fixture Simulator > Measurement > Scd21.
9. Set Scale/Div to 5 dB/div.
10. Set Reference Value to -20 dB.

6.11. CBUS Insertion Loss

1. Press
Trace Next
2. Press
Meas
> S21.
3. Press
Scale
> Set Scale/Div to 2 dB/div.
4. Press
Scale
> Set Reference Value to -8 dB.

6.12. Far-End Crosstalk

1. Press
Trace Next
2. Press
Meas
> S41.
3. Press
Scale
> Set Scale/Div to 5 dB/div.
4. Press
Scale
> Set Reference Value to -20 dB.
5. Press
Trace Next
6. Press
Meas
> S32.
7. Press
Scale
> Set Scale/Div to 5 dB/div.
8. Press
Scale
> Set Reference Value to -20 dB.

6.13. CBUS Line Capacitance

1. Press
Trace Next
2. Press
Meas
> S11.
3. Press
Format
> Lin Mag.
to select Trace 4.
to select Trace 3.
to select Trace 7.
to select Trace 8.
34