Trigger; [:Start]:Count; [:Start|Sequence[1]]; Count - HP E1340A User Manual

Arbitrary function generator
Hide thumbs Also See for E1340A:
Table of Contents

Advertisement

TRIGger[:STARt]:COUNt

TRIGger

Subsystem Syntax

[:STARt]:COUNt

Parameters
Comments
Example
186
HP E1340A Command Reference
The

TRIGger

subsystem operates with the
behavior of the trigger system, as follows:
The source for generating the individual samples of a waveform.
The total number of samples (triggers).
TRIGger

[:STARt|SEQuence[1]]

:COUNt <
:SOURce <
TRIGger[:STARt]:COUNt <
of triggers the HP E1340A would accept after an
command before returning the start trigger sequence to the wait-for-arm
state. However, since this is equal to the length of the current waveform,
and is not configurable here, the only legal value for this command is
9.91e37 or NaN (not a number).
There is no need to send this command. It is included for SCPI
compatibility purposes only.
Parameter
Parameter
Name
Type
number
numeric
MINimum and MAXimum select 9.91e37 triggers.
9.91E+37 is equivalent to NAN.
Executable when initiated: Yes
Coupled command: No
Related Commands:
*RST Condition:
Setting the start trigger count
TRIG:COUN NAN
ARM
number
>
source
>
number
would normally specify the number
>
Range of
Values
9.91e37 | NAN |
MINimum | MAXimum
ABORt, INITiate:IMMediate
TRIGger:STARt:COUNt 9.91e37
subsystem to control the
INITiate:IMMediate
Default
Units
none